UV-2C MICROPROCESSOR INTERGRATOR

UV-2C MICROPROCESSOR INTERGRATOR View larger

$2,600.00

New product

The UV-2C MICROPROCESSOR INTEGRATOR is an economical, self-contained, high quality UV measuring instrument. It is designed to measure, record and display peak UV intensity and UV dosage in the UV curing process.

+ Choice of a combination of two different spectral ranges:
+ UV-A intensity mW/cm2 + UV-V dose mJ/cm2
+ UV-B intensity mW/cm2 + UV-V dose mJ/cm2
+ UV-C intensity mW/cm2 + UV-A dose mJ/cm2
+ UV-V intensity mW/cm2 + UV-V dose mJ/cm2
+ Permanent or triggered measuring mode*
+ Re-chargeable accu cells with charger

It is equipped with two different UV sensors for the individual measuring of a combination of either:

UV-C 230 280 nm
UV-B 280 315 nm
UV-A 315 400 nm
UV-V 395 445 nm
UV 250 410 nm

With two different UV-bands, many of the measuring requirements of UV curing applications can be covered. Due to its two different UV sensors and the integrated microprocessor the UV-2C Microprocessor Integrator can measure, record and display the peak of the UV-intensity (mW/cm2) for each UV-band individually. Additionally, this UV-Integrator is calculating the UV-dosage (mJ/cm2) of the UV energy supplied during the time of exposure of one measuring cycle. The UV-dosage is calculated for each UV-band (UV-A, UV-B, UV-C or UV-V) individually. This allows to determine not only the UV-energy, but also how that energy is delivered, i.e., what intensity and dose at what UV-band. Optionally, an extra sensor measures temperatures from 32 to 230 F / 0 to 110 C.
*This Microprocessor Integrator features a selectable triggered mode, i.e. the 30 sec recording cycle starts within a 120 second readiness phase not before the incident UV-intensity exceeds 2 mW/cm.

The two sensors are on the back of the unit which also serves as a heat shield. After completion of the measuring cycle all measuring results can be scrolled through on the built in 2 x 16 digit LCD display. A special AUTO-OFF feature that turns off the unit automatically after one minute serves as energy saving and extension of the battery service life. As a further option this microprocessor integrator is available with an USB ComPort and an evaluation software for downloading the data to a computer to show, edit and store a history of the measuring results of the entire measuring cycle as graphic charts (mW/cm2) and (mJ cm2) and (F option -)

UV-2C Microprocessor Integrator UV-A + UV-V
UV-2C Microprocessor Integrator UV-A + UV-B
UV-2C Microprocessor Integrator UV + UV-A
UV-2C Microprocessor Integrator UV + UV-B
UV-2C Microprocessor Integrator UV + UV-V
UV-2C Microprocessor Integrator UV-B + UV-V
UV-2C Microprocessor Integrator UV-C + UV-V

TECHNICAL DATA
Spectral ranges: UV-A 315 410 nm, UV-V 395 445 nm , UV-B 280 315 nm, UV-C 230 280 nm
Max. Power Input 0 to 5,000 mW/cm2
Measuring range: 0 to 2,000 mW/cm2
Display range: 0 to 60,000 mJ/cm2
Sampling rate: 0.005 sec (200/sec)
Recording cycle: 30 sec.
Readiness phase: 120 sec.
Display: LCD, 2 x 16 digits
Power source: 2 x 3.7 V LiPO Accu
Power consumption: 20 A
Accu service life: 1,000 re-charging cycles
Dimensions: 5.5 (140 mm), height (13 mm)
Weight: approx. 17.5 ounce (500 g)
Operating temperature: 32 to 113 F / 0 to 45 C
Heat protection: Heat shield on back plate
Base Accuracy: 5 %

While on the conveyer belt, the UV-2C Microprocessor Integrator can withstand max. 230 F / 110 C for up to 10 seconds. The temperature of the housing should not exceed 113 F / 45 C. Because of uneven radiation distribution of the UV light source and different type of construction of the measuring devices by different manufacturers, different readings may appear under the same measurement conditions.

CALIBRATION
In order to keep its full function and precision it is recommended to have re-calibration done once per year. Re-calibration will also be necessary after change of battery. PTB traceable calibration acc. to DIN EN ISO / IEC 17025 with certificate

ATTENTION:
1. Please avoid shaking the UV-2C Microprocessor Integrator.
2. Do not expose to excessive heat.
3. UV-light is hazardous to your health. Avoid direct UV-light to your eyes and to your body.

Datasheet_UVPS.gif
Download Datasheet:
UV-2C Micro Processor Integrator.pdf

 

-->